A lot of home water and electricity will go underground pipe, so it looks beautiful and clean
.
However, if the “hidden pipe” can not be seen, it is easy to be greasy in the construction of water and electricity
.
Some bad workers cut corners and bully the owners
.
In the construction process, they use convenient technology and inferior materials, which will certainly cause problems in the later stage
.
Mr
.
Wang, the owner, found the construction problems during the acceptance of water and electricity
.
The owner said that my family had just finished water and electricity and was ready for acceptance
.
However, in the process of acceptance, it was found that the fixing method of line pipe and switch bottom box was very strange, which was different from what we saw on the Internet and other people’s homes
.
At that time, the workers and I said that this fixing method was a new technology
.
But I don’t feel at ease
.
I took photos on the spot and sent a circle of friends for consultation
.
A friend who is familiar with the decoration said that this is not the new craft that the workers said, but the real shoddy work! What did the workers do? Problem 1: cement is not used to fix the line pipe and switch bottom box
.
Workers not only do this in the living room and bedroom, but also use foaming agent to fix the line pipe and switch bottom box in wet areas such as kitchen and toilet
.
As the foaming agent has a certain degree of shrinkage, with the passage of time, the bonding degree of foaming agent will be greatly reduced, which will lead to wall cracking, socket panel loosening or even falling off
.
Therefore, it is strictly forbidden to use foaming agent to fix wires, pipelines and bottom boxes in decoration
.
The correct way is to use cement to fix, and the interior should be filled, so as to avoid the cracking of the wall slotting, and ensure the firmness of the switch and socket
.
The purpose of workers doing this is to facilitate the construction, which is much faster than using cement mortar to fix, which can save time to take more work, and the price of a can of foaming agent is not expensive, and the poor quality is only more than ten yuan
.
Problem 2: the position of the distribution box is not reasonable
.
The position of the distribution box is not much higher than the height of the switch
.
The appropriate switch height is 120cm-140cm, so the height of the distribution box is expected to be about 170cm, and it is close to the door, so that the owners will have more trouble in dealing with the distribution box in the future
.
Problem 3: the wall slotting is not standardized
.
There are problems in the wall slotting
.
Many load-bearing walls are longer than 50cm when they are slotted, which has a certain impact on the load-bearing of the wall
.
When decorating, the load-bearing wall should not be opened without transverse groove
.
If it cannot be avoided, the length should be controlled
.
Generally, the length should not exceed 50cm, and the width and depth of groove also need to be controlled
.
Therefore, the owner must be careful in the acceptance, and even ask professional people to assist in the acceptance of water and electricity, so as to avoid unnecessary trouble in the later period【 Disclaimer]
.