Be careful to drive a ten thousand year ship, the five most wrong construction of hydropower decoration! Lessons learned after suffering

Luneng Taishan wire 10.

Hydropower transformation is not only the first construction project of home decoration, but also the most important one! Once it is not handled properly, it will bury major hidden dangers for the new home! Therefore, we must understand the common mistakes in hydropower transformation, especially the following five.

The gain is not worth the loss! National standard water pipe materials and wires must pass CCC National Compulsory Certification.

The wiring rules shall follow the principle of “live wire into the switch and zero wire into the lamp cap”.

Domestic top ten wire brands: 1.

In some locations, two points and one line can also be nearby! All pipelines are overlapped by bridges.

Domestic well-known brands are used for wires and water pipes.

In case of water leakage, we can happen immediately, so as not to be buried in the ground.

Bad luck may lead to electric shock and fire accidents! National standard strong and weak current must be wired separately, not in the same slot, let alone the same tube and the same bottom box! It is emphasized that the parallel spacing of reverse lines shall not be less than 30cm, preferably 50cm.

Far East wire 2.

RiFeng water pipe 3 Weixing water pipe 4, Jinniu water pipe 5, Zhongcai water pipe 6, Liansu water pipe 7, Tongde water pipe 8, ad water pipe 9, German standard water pipe 10, GuDi water pipe 2.

When making hydropower due to the consequences of wrong hydropower design layout, the most afraid thing is to despise the hydropower layout and design, and how many are installed! Even in order to save money, directly use the open merchant intact! You should know that the socket can’t be installed when you buy it from the roadside supermarket.

It is also convenient to repair what happens in the later stage.

Therefore, you often see that there are wiring boards in other people’s homes, and the wiring board is far from safe as the socket after a long time! If multiple plugs are inserted into one socket and several devices are used at the same time, accidents are easy to occur! Before the construction of national standard hydropower transformation, professional electricians shall be invited first, and the power plugs shall be reasonably arranged according to the housing area, the number of sockets in square meters required for life, and the actual number of household electrical appliances.

Hengtong photoelectric wire 8.

Zhejiang cable wire 6.

The socket must be equipped with leakage protection device! For high standard construction, strong and weak electricity must be separated, and lock catch must be used when connecting wire tube and cassette.

If the circuit connection is not standardized, the consequences of errors must be guaranteed, otherwise life may be in danger! Several common construction errors in circuit transformation are: common management of strong and weak electricity, repeated wiring, direct naked burial of wires without pipe sleeves, and random installation of socket wires.

Some sockets are reserved for later expansion! Before the construction of high standard construction water and electricity, the basic number and installation position of sockets shall be designed.

Domestic top ten water pipe brands: 1.

Jinde water pipe 2.

Plate Anchor

Ensure that the wire is a live wire and that the whole wire in the pipe can be pulled! High standard water and electricity construction adopts the principle of horizontal and vertical, not big bends.

Before the construction, communicate with the designer how to arrange the electrical appliances and where to stay and play with the mobile phone.

Baosheng wire.

On the one hand, it is safer to separate from the circuit.

Once we make a mistake, it will do great harm to the decoration! 1.

Once the water and electricity decoration is over, you can only endure if the socket is not enough.

These four major errors! These construction problems are just use failures.

Wires should be color separated and PVC flame-retardant wire pipes should be used! Lay the wire horizontally and vertically, use a pipe clamp every 80 cm for the straight pipe, use a lock nut at the connection between the wire box and the wire pipe, and use a pipe clamp every 20 cm at the corner of the wire pipe.

Zhujiang wire 4.

The socket position shall be customized according to the customer, and the position, height and number of each socket shall be confirmed one by one before construction.

Shangshang wire 5.

After all, not every set of design is with everyone! Also avoid potential circuit accidents! 3.

Hongyan wire 9.

Panda wire 3.

As a result, the probability of water pipe leakage increases sharply due to random installation! It has a great impact on future maintenance! National standard waterway construction must also be designed and have basic laws! Parallel to the wall, avoid the electric conduit! In case of water leakage accident, it will not affect the short circuit of wires! Cause extensive damage! For high standard construction, first of all, the laying of water pipes should be carried out in strict accordance with the water and electricity construction standards.

The most common construction mistakes are that the water route is not standardized, the water pipe has no design direction, the water pipe is bent arbitrarily, and all the water pipes go underground! Many people think that water pipes are not like wires, so they don’t have to pay so much attention.

The consequences of wrong materials for hydropower are well known.

The cross section of the wire in the pipe shall not exceed 40% of the total area.

When the floor is completely wet, we don’t know! Before laying water and electricity pipes, snap the line and confirm the specific line before construction! When the wire pipe and water supply pipe cross, the wire pipe should be above the water pipe! 4.

Panda wire 7.

The electric box in the same direction shall be placed in the same pipe, and the inside and outside of the wire must be protected by insulating sleeve! The connector shall not be exposed.

After the completion of hydropower transformation, electric wires and water pipes are buried in the ground and walls! We all know that when we do decoration, we are most afraid to hear that there are problems with water and electricity, because maintenance is really too troublesome! Moreover, the poor quality of water pipes and wires can easily lead to safety accidents! I met many owners who chose low-quality hydropower materials because of the provincial budget, and finally all the pipes and wires were removed.

The live line, zero line and bottom line in the wire pipe shall be separated..

All wires shall be made into “live wire”.