14.
Reserved openings: openings larger than 25cm shall be protected with fixed cover plates, and two horizontal railings shall be set around openings larger than 50cm, with a height of no less than 1m.
5.
On site fire prevention: the floors of woodworking room, canteen, dormitory area and operation area must be equipped with fire-fighting equipment, and the dangerous places must be hung with no fireworks signs.
In addition to two horizontal railings, a safety flat net must be set up under the hole with a diameter of more than 1m.
1.
9.
What should we start from when we just enter the cost industry?..
2.
Brick fences should have wall caps and walls should have propaganda slogans.
A light box is set on the top of the door, with the name of the enterprise and the name of the project on it.
Scaffold: it is strictly forbidden to mix steel and wood.
Dangerous area: danger signs such as “no”, “warning” shall be hung in the dangerous area at the site operation point.
The guard room shall have a guard system.
It is not allowed to pile soil, materials and machinery within 1m of the pit (groove) ditch edge.
QQ group 925078799, password? How to improve the level of project cost audit? Do you make the difference between the four grades of project manager a, B, C and D? The difference between the first construction and the second construction, the “crooked brain” of the budgeter, which makes the completion settlement faster.
Construction site fence: closed with hard materials or brick masonry (the wall height of main urban sections is 2.5m and that of general sections is 1.8m.) The wall shall be plastered and whitewashed to be firm, stable, neat and beautiful.
The shed length shall be greater than 3m; Double layer protection shall be set above 24m high, with an interval of no less than 60cm and a shed length of more than 10m.
Project licenses: business license (original and duplicate), enterprise qualification (original and duplicate), safety license (original and duplicate), safety qualification certificate of enterprise legal person, safety leader in charge and enterprise safety director, safety management network diagram, Safety Production assurance system, safety production responsibility system at all levels Certificate of responsibility for safe production (signed level by level until workers), qualification certificate and employment of full-time safety officer of project department, employment of team safety officer, documents and schemes related to safe production, etc.
Seven pictures and three signs are hung inside the door.
The safety belt should be hung high and used low.
Elevator wellhead: a fixed gate grid or two protective fences with a height of no less than 1.2m shall be set (one at 60cm and one at 120cm respectively), and a flat net shall be set every 10m in the elevator room.
Site gate: set gate stack and gate.
The canteen shall be provided with screen windows, screen doors, screen covers, hung with health permits, health responsibility system, etc.
11.
12.
Storage of gas cylinders: oxygen cylinders and acetylene cylinders are more than 5m apart and 10m away from the open fire.
8.
13.
Material stacking: it shall be stored in order by category, marked and provided with site plan.
The operators shall have a physical examination and health certificate, and the raw and cooked food shall be separated.
Color profiled steel plate can be used if conditions permit.
Living logistics: no one is allowed to live in the construction in progress.
16.
If the scaffold is not removed, it is not allowed to dig foundation on the side.
Materials or soil shall not be stacked near the wall.
Clothes are not allowed to hang on scaffolds or wires.
7.
Urinals are set in high-rise buildings.
Site floor: implement hard floor with good drainage (the site is hardened, and the main road in the site is not less than 20m, and not less than 5m outside the site) and equipped with flushing platform.
6.
The on-site canteen shall comply with the regulations.
15.
3.
Construction pit and groove: when the depth of the excavated pit (groove) is more than 1.5m, it must be sloped or reliably supported.
10.
They cannot be exposed to the sun, and acetylene cylinders cannot be placed horizontally.
The material meets the standard.
It is strictly prohibited to urinate anywhere.
Personal protection: wear safety helmet and fasten safety belt.
Edge protection: balcony, roof, floor, staircase, unloading platform and other edge facilities shall be provided with two protective railings, one for each 60 cm and 120 cm high, and columns shall be set if the spacing is greater than 2m.
When it is more than 2m, two guardrails must be set around, with a height of 1.2m, the spacing between upright rods shall not be greater than 2m, and the upper and lower channels shall be set up stably and non slip.
Site access: a protective shed shall be set up at the entrance, the shed width shall be greater than the crossing, and the shed top shall be fully covered with scaffold board.
At the gate, “important construction land, no admittance for idle people” is placed And “safety helmets must be worn at the construction site.” Brand.
4.
The “three treasures” must have production license, product certificate and quality inspection certificate.